建立了络合掩蔽-离子色谱法,测定氯亚钯酸(H2PdCl4)溶液中的硝酸根含量。用乙二胺(en)将阴离子[PdCl4]2-转化为[Pd(en)2]2+阳离子,用银柱除氯,避免大量氯离子拖尾影响阴离子的测定。采用高容量阴离子色谱柱,以5-15-35-5 mmol/L KOH在线梯度淋洗,抑制电导检测氯亚钯酸中的硝酸根含量。结果表明,常见阴离子对测定结果无干扰,方法在0.05~4.0 μg/mL浓度范围内有良好的线性关系,相对标准偏差为0.8%~3.4%,加标回收率为93%~110%,满足产品质量检测要求。 |
英文摘要: |
A method for the detection of nitrate in H2PdCl4 by complex masking-ion chromatography was established. The anionic PdCl42- was first converted to Pd(en)22+ cations with ethylenediamine (en). A silver column were used to eliminate chlorine, so as to avoid the trailing effect caused by a large amount of chloride ion. A high capacity anion chromatographic column was selected for the determination of nitrate in chloropalladium acid with 5-15-35-5 mmol/L KOH as on-line gradient elution. The results showed that the common anions did not interfere with the determination results, and the method had a good linear relationship in the concentration range of 0.05~4.0 μg/mL. The relative standard deviation was 0.8%~3.4% while the spiked recovery ranged from 93% to 110%. The established method can meet the requirements of the quality testing for H2PdCl4. |