Abstract
锡试金分离富集-ICP-MS法同时测定地质样品中的金铂钯
Determination of Au, Pt and Pd in Geological Samples by Inductively Coupled Plasma Mass Spectrometry with Tin Fire Assay
Received:December 20, 2012  
DOI:
中文关键词: 分析化学  锡试金  地质样品  电感耦合等离子体质谱法(ICP-MS)  测定金、铂、钯
英文关键词: analytical chemistry  tin fire assay  geological samples  inductively coupled plasma mass spectrometry (ICP-MS)  determination of Au, Pt and Pd
基金项目:国土资源部公益性行业专项(200911043-01)资助。
Author NameAffiliationE-mail
TANG Zhizhong Key Lab of Ministry of Land and Resources Analysis and Exploration of Precious Metals,Henan Rock Mineral Testing Centers, Zhenzhou 450012, China cszxtang@163.com 
WANG Junyu Key Lab of Ministry of Land and Resources Analysis and Exploration of Precious Metals,Henan Rock Mineral Testing Centers, Zhenzhou 450012, China junyu65@126.com 
SUN Honglin Key Lab of Ministry of Land and Resources Analysis and Exploration of Precious Metals,Henan Rock Mineral Testing Centers, Zhenzhou 450012, China  
WANG Meiying Key Lab of Ministry of Land and Resources Analysis and Exploration of Precious Metals,Henan Rock Mineral Testing Centers, Zhenzhou 450012, China  
LI Yanhua Key Lab of Ministry of Land and Resources Analysis and Exploration of Precious Metals,Henan Rock Mineral Testing Centers, Zhenzhou 450012, China  
LI Jie Key Lab of Ministry of Land and Resources Analysis and Exploration of Precious Metals,Henan Rock Mineral Testing Centers, Zhenzhou 450012, China  
CHEN Jing Key Lab of Ministry of Land and Resources Analysis and Exploration of Precious Metals,Henan Rock Mineral Testing Centers, Zhenzhou 450012, China  
Hits: 4051
Download times: 4911
中文摘要:
      以锡作捕集剂,通过调整试金配料,将熔矿温度提高到1100℃,解决了锡试金熔炼困难、不易成扣和扣回收不稳定现象。通过增加助熔剂和覆盖剂,改进了熔渣流动性及样品溢出的问题。对捕集了贵金属的锡扣用盐酸溶解锡、镍等,过滤后王水溶解金、铂、钯沉淀物,并用电感耦合等离子体质谱法测定。对国家标准物质的分析结果与标准值相一致,各元素的RSD在5%~14%之间。对5个地质样品进行结果比对,采用锡试金法与铅试金法前处理测得的金、铂、钯结果相符。该方法在生产实践中已得到了应用,适用于地质样品中金、铂、钯的分析。
英文摘要:
      The difficulties of tin melting and the button recovery instability were solved by using the trapping agent of tin, adjusting the assay ingredient and increasing the molten ore temperature to 1100℃. Meanwhile, the slag fluidity and the overflow of the sample were improved by adding the flux and covering agent. Tin button with precious metal was dissolved and filtered, then the residue was dissolved with aqua regia and diluted with water. Au, Pt and Pd were determined by ICP-MS. The analysis results were consisted with standard values of the national standard reference materials, and the RSD value was 5%~14%. Au, Pt and Pd in geological samples were determined with tin fire assay method and lead fire assay method respectively, and their results are consistent. This method is suitable for the determination of Au, Pt and Pd in geological samples.