Author Name | Affiliation | E-mail | WANG Fang | Analysis and Testing Center, Guangzhou Research Institute of Non-ferrous Metals, Guangzhou 510650, China | wflicp@163.com | CHEN Xiaolan | Analysis and Testing Center, Guangzhou Research Institute of Non-ferrous Metals, Guangzhou 510650, China | | LIN Haishan | Analysis and Testing Center, Guangzhou Research Institute of Non-ferrous Metals, Guangzhou 510650, China | | LI Xiaoling | Analysis and Testing Center, Guangzhou Research Institute of Non-ferrous Metals, Guangzhou 510650, China | | XIAO Hongxin | Analysis and Testing Center, Guangzhou Research Institute of Non-ferrous Metals, Guangzhou 510650, China | |
|
Hits: 5089 |
Download times: 5065 |
中文摘要: |
通过铅试金富集树脂中的钯并用银作钯灰吹保护,得到的银钯合粒用王水溶解,在5%的盐酸介质中,采用原子吸收光谱法测定钯,该法测钯的相对标准偏差RSD为0.53%,加标回收率在99.04%~100.10%之间。 |
英文摘要: |
Palladium in resin was enriched by lead assaying, using silver as a protective agent to produce silver-palladium alloy, and then the alloy was dissolved in aqua regia. Air acetylene flame atomic absorption spectrometric method was used to determinate palladium in 5% hydrochloric acid solution. The relative standard deviation (RSD) in determination of palladium is 0.53% and the recovery rate is between 99.04%~100.10%. |