Abstract
铅试金富集-火焰原子吸收光谱法测定树脂中钯
Determination of Palladium in Resin by Lead Fire Assaying – Flame Atomic Absorption Spectrometric Method
Received:April 08, 2013  
DOI:
中文关键词: 分析化学  铅试金  原子吸收光谱法  
英文关键词: analytical chemistry  lead assaying  atomic absorption spectrometry  palladium
基金项目:
Author NameAffiliationE-mail
WANG Fang Analysis and Testing Center, Guangzhou Research Institute of Non-ferrous Metals, Guangzhou 510650, China wflicp@163.com 
CHEN Xiaolan Analysis and Testing Center, Guangzhou Research Institute of Non-ferrous Metals, Guangzhou 510650, China  
LIN Haishan Analysis and Testing Center, Guangzhou Research Institute of Non-ferrous Metals, Guangzhou 510650, China  
LI Xiaoling Analysis and Testing Center, Guangzhou Research Institute of Non-ferrous Metals, Guangzhou 510650, China  
XIAO Hongxin Analysis and Testing Center, Guangzhou Research Institute of Non-ferrous Metals, Guangzhou 510650, China  
Hits: 5089
Download times: 5065
中文摘要:
      通过铅试金富集树脂中的钯并用银作钯灰吹保护,得到的银钯合粒用王水溶解,在5%的盐酸介质中,采用原子吸收光谱法测定钯,该法测钯的相对标准偏差RSD为0.53%,加标回收率在99.04%~100.10%之间。
英文摘要:
      Palladium in resin was enriched by lead assaying, using silver as a protective agent to produce silver-palladium alloy, and then the alloy was dissolved in aqua regia. Air acetylene flame atomic absorption spectrometric method was used to determinate palladium in 5% hydrochloric acid solution. The relative standard deviation (RSD) in determination of palladium is 0.53% and the recovery rate is between 99.04%~100.10%.
View Full Text   View/Add Comment  Download reader