Abstract
湿法分解—ICP-AES测定废钯碳催化剂中的钯
Determination of Palladium in Spent Palladium Carbon Catalyst by ICP-AES
Received:April 09, 2013  
DOI:
中文关键词: 分析化学  湿法分解  钯炭催化剂    等离子体发射光谱
英文关键词: analytical chemistry  wet decomposition  Pd/C catalyst  palladium  ICP-AES
基金项目:广东省重大专项“废杂铜环保利用与再生关键技术及装备研究”(2012A090300008)资助。
Author NameAffiliationE-mail
XIAO Hongxin Guangdong General Research Institute for Industrial Technology, Guangzhou 510651, China xiaohx168@163.com 
YUE Wei Guangdong General Research Institute for Industrial Technology, Guangzhou 510651, China  
ZHUANG Aichun Guangdong General Research Institute for Industrial Technology, Guangzhou 510651, China  
WANG Fang Guangdong General Research Institute for Industrial Technology, Guangzhou 510651, China  
CHEN Xiaolan Guangdong General Research Institute for Industrial Technology, Guangzhou 510651, China  
LIN Haishan Guangdong General Research Institute for Industrial Technology, Guangzhou 510651, China  
LI Xiaolin Guangdong General Research Institute for Industrial Technology, Guangzhou 510651, China  
WANG Caihua Guangdong General Research Institute for Industrial Technology, Guangzhou 510651, China  
Hits: 3953
Download times: 4409
中文摘要:
      为完全分解样品,消除碳的影响,以H2SO4+HNO3冒烟消除碳,甲酸还原,王水溶解,在ICP-AES选定的条件下测定废钯炭催化剂样品中钯的含量。样品加标回收率97.0%~101.6%,测定0.099%~0.324%的钯含量,相对标准偏差2.55%~2.84%,方法与灼烧还原法及火试金法测定结果一致,方法简单快速,环保节约,结果准确。
英文摘要:
      In order to decomposes the sample completely and eliminate the impact of carbon, preparation of sample, carbon removed by H2SO4+HNO3 smoking, formic acid reduction, dissolved by aqua regia. determine palladium content in the selected conditions of ICP-AES. The recovery ranged from 97.0% to 101.8%, the relative standard deviation (n=6) is less than 3%, determination result of the method and method of ignition reduction and fire assay is consistent, the method is simple and fast, environmental protection, conservation, and accurate.