Abstract
ICP-AES法测定钯炭中铅、铜和铁量
Determination of Lead, Copper and Iron Contents in Palladium-Carbon by ICP-AES
Received:January 05, 2015  
DOI:
中文关键词: 分析化学  电感耦合等离子体-原子发射光谱法  钯炭      
英文关键词: analytical chemistry  ICP-AES  palladium-carbon  lead  copper  iron
基金项目:
Author NameAffiliationE-mail
REN Chuanting State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co. Ltd., Kunming Institute of Precious Metals, Kunming 650106, China flytosky1023@163.com 
XU Guang State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co. Ltd., Kunming Institute of Precious Metals, Kunming 650106, China  
TANG Fajing State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co. Ltd., Kunming Institute of Precious Metals, Kunming 650106, China  
LI Qing State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co. Ltd., Kunming Institute of Precious Metals, Kunming 650106, China  
MA Yuan State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co. Ltd., Kunming Institute of Precious Metals, Kunming 650106, China  
FANG Wei State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co. Ltd., Kunming Institute of Precious Metals, Kunming 650106, China  
LI Guangli State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co. Ltd., Kunming Institute of Precious Metals, Kunming 650106, China  
GAN Jianzhuang State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co. Ltd., Kunming Institute of Precious Metals, Kunming 650106, China  
Hits: 4615
Download times: 4538
中文摘要:
      采用硝酸-高氯酸分解试样,ICP-AES法同时测定铅、铜和铁。建立了一个准确、快速、简便的测定方法,适用于新制和失效钯炭中铅、铜和铁量的测定。Pb、Cu、Fe测定范围为0.01%~0.1%;方法的加标回收率为95.8%~100.9%;相对标准偏差RSD<5%。
英文摘要:
      A simple accurate and precise analytical method for the determination of lead, copper and iron in palladium-carbon catalysts by ICP-AES was proposed. The digestion of sample which contains lead, copper and iron in the range between 0.01%~0.1% in fresh or spent palladium-carbon, was obtained using both HNO3 and HClO4. The recoveries were ranged from 95.8% to 100.9%. The precision, expressed as relative standard deviation (RSD) of the method, is better than 5%.