Abstract
密闭消解-光度法测定乙醇胺羟基铂中的铂含量
Determination of the Content of Platinum in Ethanol Amine Hydroxyl Platinum by Sealed Digestion and Spectrophotometry
Received:June 25, 2015  
DOI:
中文关键词: 分析化学  乙醇胺羟基铂    消解方法  分光光度法
英文关键词: analytical chemistry  ethanolamin ehydroxyl platinum  platinum  digestion methods  spectrophotometry
基金项目:
Author NameAffiliationE-mail
SHA Jiao State-Local Joint Engineer Laboratory of Precious Catalytic Technology and Application,Kunming Sino-Platinum Metals Catalyst Co. Ltd., Kunming 650106, China shajiaoli@163.com 
YANG Dongxia State-Local Joint Engineer Laboratory of Precious Catalytic Technology and Application,Kunming Sino-Platinum Metals Catalyst Co. Ltd., Kunming 650106, China  
XU Lian State-Local Joint Engineer Laboratory of Precious Catalytic Technology and Application,Kunming Sino-Platinum Metals Catalyst Co. Ltd., Kunming 650106, China  
HUANG Yao State-Local Joint Engineer Laboratory of Precious Catalytic Technology and Application,Kunming Sino-Platinum Metals Catalyst Co. Ltd., Kunming 650106, China  
LI Quan State-Local Joint Engineer Laboratory of Precious Catalytic Technology and Application,Kunming Sino-Platinum Metals Catalyst Co. Ltd., Kunming 650106, China  
ZHAO Li State-Local Joint Engineer Laboratory of Precious Catalytic Technology and Application,Kunming Sino-Platinum Metals Catalyst Co. Ltd., Kunming 650106, China  
BI Xiangguang State-Local Joint Engineer Laboratory of Precious Catalytic Technology and Application,Kunming Sino-Platinum Metals Catalyst Co. Ltd., Kunming 650106, China  
QIAN Haifu State-Local Joint Engineer Laboratory of Precious Catalytic Technology and Application,Kunming Sino-Platinum Metals Catalyst Co. Ltd., Kunming 650106, China  
ZHAO Yunkun State-Local Joint Engineer Laboratory of Precious Catalytic Technology and Application,Kunming Sino-Platinum Metals Catalyst Co. Ltd., Kunming 650106, China yunkunzhao@163.com 
Hits: 4992
Download times: 4288
中文摘要:
      采用密闭法进行乙醇胺羟基铂的消解,用氯化亚锡光度法进行样品中铂的测定。实验表明,在160℃聚四氟乙烯密闭消解罐中,用12 mL HNO3-3 mL H2O2经6 h可消解3 mL样品;在盐酸介质中,Pt(IV)与SnCl2反应生成稳定的橙黄色络合物,在波长403 nm处进行分光光度法测定,铂量在0~20 mg /L范围内符合朗伯-比尔定律。对乙醇胺羟基铂样品中35.82~42.55 g/L 铂进行测定,相对标准偏差(RSD)和样品加标准回收率分别为0.072%~0.11%和99.3%~102.8%,与电流滴定法和氯铂酸铵重量法的测定结果吻合。
英文摘要:
      Using the sealed digestion method of ethanolamine hydroxyl platinum, and content of platinum in sample was determined by SnCl2 spectrophotometry. The results showed that 3 mL ptoctanoate tlimer sample could be digested completely with 12 mL HNO3 and 3 mL H2O2 at 160℃ in a PTFE Jar for 6 h. In hydrochloric acid medium, Pt(IV)-SnCl2 forms a orange stable complex with stannous chloride. The platinum sample was determined by spectrophotometry at the wavelength of 403 nm, the result shows Beer’s Law is obeyed in the range of 0~20 mg/L. The samples of hydroxyl ethanolamine platinum were determined for Pt content from 35.8~42.55 g/L, the relative standard deviations (RSD) and the recoveries of standard addtion are 0.072%~0.11% and 99.3%~102.8%, respectively. The result is coincided with that of the amperometric titration and ammonium chloroplatinate gravimetry.