Abstract
离子色谱法同时测定硫酸钯溶液中的氯离子和硝酸根
Simultaneous Determination of Chloride and Nitrate Ions in PdSO4 Solution by Ion Chromatography
Received:December 20, 2016  
DOI:
中文关键词: 分析化学  离子色谱  硫酸钯溶液  氯离子  硝酸根离子
英文关键词: analytical chemistry  ion chromatography (IC)  palladium(II) sulfate solution  chloride ion  nitrate ion
基金项目:稀贵金属综合利用新技术国家重点实验室开放课题(SKL-SPM-201543)。
Author NameAffiliationE-mail
SU Linlin State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co.Ltd., Kunming 650106, China sulin@ipm.com.cn 
ZUO Chuan State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co.Ltd., Kunming 650106, China  
HOU Wenming State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co.Ltd., Kunming 650106, China hwm@ipm.com.cn 
YU Mingkun Yunnan Institute of Building Research, Kunming 650223, China  
HAN Yuan State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co.Ltd., Kunming 650106, China  
FENG Lu State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co.Ltd., Kunming 650106, China  
WEI Jianwei Sino-Platinum Industrial Catalyst Yunnan Co.Ltd., Kunming 650106, China  
XU Mingming State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co.Ltd., Kunming 650106, China  
Hits: 2676
Download times: 2582
中文摘要:
      建立了离子色谱法同时测定贵金属化合物硫酸钯溶液中的氯离子和硝酸根离子含量的方法。使用IC-H型阳离子交换前处理柱除去样品中的钯(II)阳离子;采用梯度淋洗程序,以KOH溶液(1.0 mL/min)淋洗液,用抑制性电导检测,外标法定量测定氯离子和硝酸根离子。测定线性范围为0.04~1.2 μg/mL,检出限为0.006~0.015 μg/mL,相对标准偏差(RSD)为2.5%~4.9%,样品加标回收率94.2%~112.9%,可满足硫酸钯溶液产品中氯离子和硝酸根离子杂质测定要求。
英文摘要:
      An ion chromatographic method has been established for measuring the concentrations of chloride and nitrate ions in the palladium(II) sulfate solution. The samples were pretreated with IC-H cation exchange resin to eliminate the interference from Pd(II) cations. Following the gradient elution with KOH solution at a speed of 1.0 mL/min), the two anions were detected simultaneously by the suppressed conductivity detector and their concentrations were calculated by external standard method. Under the optimum conditions, the linear range of the method was 0.04~1.2 μg/mL, and the limit of detection was 0.006~0.015 μg/mL. The recoveries were found to be in the range of 94.2%~112.9% with the relative standard deviation of 2.5%~4.9%. The method could be applied to the determination of Cl- and NO3- in the product of palladium(II) sulfate solution.