酸分解-容量法测定四(三苯基膦)钯中的钯含量 |
Volumetric Determination of Palladium Content in Tetrakis(triphenylphosphine) Palladium Decomposed by Acid |
Received:September 11, 2017 |
DOI: |
中文关键词: 分析化学 四(三苯基膦)钯 钯 硝酸-高氯酸 发烟分解 容量法 |
英文关键词: analytical chemistry tetrakis(triphenylphosphine) palladium palladium HNO3-HClO4 smoke decomposition volumetric method |
基金项目: |
Author Name | Affiliation | E-mail | LU Ruizhi | Kunming Institute of Precious Metals, State Key Laboratory of Advanced Technologies for ComprehensiveUtilization of Platinum Metals, Sino- Platinum Metals Co. Ltd., Kunming 650106, China | 446158964@qq.com | JIN Yaqiu | Kunming Institute of Precious Metals, State Key Laboratory of Advanced Technologies for ComprehensiveUtilization of Platinum Metals, Sino- Platinum Metals Co. Ltd., Kunming 650106, China | jyq@ipm.com.cn | YANG Xiaotao | Kunming Institute of Precious Metals, State Key Laboratory of Advanced Technologies for ComprehensiveUtilization of Platinum Metals, Sino- Platinum Metals Co. Ltd., Kunming 650106, China | | ZENG Hefeng | Kunming Institute of Precious Metals, State Key Laboratory of Advanced Technologies for ComprehensiveUtilization of Platinum Metals, Sino- Platinum Metals Co. Ltd., Kunming 650106, China | | FU Shimei | Kunming Institute of Precious Metals, State Key Laboratory of Advanced Technologies for ComprehensiveUtilization of Platinum Metals, Sino- Platinum Metals Co. Ltd., Kunming 650106, China | | MA Yuan | Kunming Institute of Precious Metals, State Key Laboratory of Advanced Technologies for ComprehensiveUtilization of Platinum Metals, Sino- Platinum Metals Co. Ltd., Kunming 650106, China | | GAN Jianzhuang | Kunming Institute of Precious Metals, State Key Laboratory of Advanced Technologies for ComprehensiveUtilization of Platinum Metals, Sino- Platinum Metals Co. Ltd., Kunming 650106, China | |
|
Hits: 2246 |
Download times: 0 |
中文摘要: |
采用硝酸溶解四(三苯基膦)钯样品,高氯酸发烟分解有机物,以络合滴定法测定钯含量。对样品发烟分解条件进行了详细考察,结果表明,高氯酸残留量在1.0 mL以内,经3次发烟可完全分解有机物。采用丁二肟析出-EDTA络合滴定法测定钯,所得结果相对标准偏差(RSD)为0.28%,加标回收率为99.66%~100.04%,满足样品中钯含量测定的要求。 |
英文摘要: |
: Samples were digestion by HNO3-HClO4 , then dissolved with HNO3-HCl. Using EDTA complexometric, ZnNO3 back titration by dioxime precipitation determinated palladium content in samples. The method discussed conditions of digestion by HNO3-HClO4. The results showed that the residual amount of HClO4 was within 1.0 mL, and the organic matter was decomposed completely by 3 times of smoke. The standard recovery rate was 99.66%~100.04%, and the relative standard deviation (RSD) was 0.28%. These results meet the requirements of determination palladium. |
View Full Text
View/Add Comment Download reader |
Close |
|
|
|