Abstract
乙酸乙酯萃取-ICP-MS测定高纯金中杂质元素含量
Determination of impurity elements in high purity gold by ethyl acetate extraction-ICP-MS
Received:May 25, 2020  
DOI:
中文关键词: 分析化学  高纯金  萃取  内标法  电感耦合等离子体质谱(ICP-MS)
英文关键词: analytical chemistry  high purity gold  extraction  internal standard method  ICP-MS
基金项目:
Author NameAffiliationE-mail
HONG Bo National Quality Supervisition and Inspection Center for Gold and Silver Products Changchun,Changchun Gold Research Institute Co. Ltd., Changchun 130012, China 690446519@qq.com 
CHEN Yong-hong National Quality Supervisition and Inspection Center for Gold and Silver Products Changchun,Changchun Gold Research Institute Co. Ltd., Changchun 130012, China  
LU Xin-gen National Quality Supervisition and Inspection Center for Gold and Silver Products Changchun,Changchun Gold Research Institute Co. Ltd., Changchun 130012, China  
SU Guang-dong National Quality Supervisition and Inspection Center for Gold and Silver Products Changchun,Changchun Gold Research Institute Co. Ltd., Changchun 130012, China  
YANG Xing National Quality Supervisition and Inspection Center for Gold and Silver Products Changchun,Changchun Gold Research Institute Co. Ltd., Changchun 130012, China  
ZHANG Yue National Quality Supervisition and Inspection Center for Gold and Silver Products Changchun,Changchun Gold Research Institute Co. Ltd., Changchun 130012, China  
YIN Chun-yu National Quality Supervisition and Inspection Center for Gold and Silver Products Changchun,Changchun Gold Research Institute Co. Ltd., Changchun 130012, China  
Hits: 1175
Download times: 685
中文摘要:
      采用乙酸乙酯萃取分离金基体,用电感耦合等离子体质谱(ICP-MS)内标法测定高纯金中31种杂质元素。萃取酸度为1 mol/L HCl,用25 mL乙酸乙酯可去除金基体对待测元素的干扰,对金的萃取率大于99.9%。将31种元素用45Sc、133Cs、159Tb、187Re等4个内标元素分组测定。方法检出限为0.25 μg/L,定量限为0.83 μg/L,精密度(RSDn=12)为0.31%~5.97%,加标回收率为95.3%~109.2%。可满足99.999%的高纯金样品中杂质元素含量的检测。
英文摘要:
      The gold matrix was extracted and separated by ethyl acetate solvent, and 31 impurity elements in high purity gold were determined by inductively coupled plasma mass spectrometry (ICP-MS). The extraction rate of gold was more than 99.9% when gold solution was extracted by 25 mL ethyl acetate in 1 mol/L HCl solution. 31 impurities were divided into 4 groups with 45Sc, 133Cs, 159Tb, 187Re as internal standard elements. The method has a detection limit (DL) of 0.25 μg/L, limit of quantitation (LOD) of 0.83 μg/L, precision (RSDn=12) range of 0.31%~5.97%,and standard recovery ratio of 95.3%~109.2%. The method can satisfy the determination of impurities in 99.999% high purity gold samples.
View Full Text   View/Add Comment  Download reader
Close