草酸银中银的还原重量法测定 |
Determination of silver content in silver oxalate by reduction gravimetric method |
Received:October 15, 2020 |
DOI: |
中文关键词: 重量法 水合肼还原 草酸银 银含量 |
英文关键词: gravimetric method reduction of hydrazine hydrate silver oxalate silver content |
基金项目: |
Author Name | Affiliation | E-mail | GUAN You-xiang* | Yongxing Sino-Platinum Metals Resources Co.Ltd., Chenzhou 423399, Hunan, China State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co.Ltd., Kunming 650106, China | 2432028977@qq.com | LI Kun | Yongxing Sino-Platinum Metals Resources Co.Ltd., Chenzhou 423399, Hunan, China State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co.Ltd., Kunming 650106, China | | LIU Li | Yongxing Sino-Platinum Metals Resources Co.Ltd., Chenzhou 423399, Hunan, China | | PENG Chun-sheng | Yongxing Sino-Platinum Metals Resources Co.Ltd., Chenzhou 423399, Hunan, China | | WANG Lin-na | Yongxing Sino-Platinum Metals Resources Co.Ltd., Chenzhou 423399, Hunan, China | | CAO Peng-bin | Yongxing Sino-Platinum Metals Resources Co.Ltd., Chenzhou 423399, Hunan, China | | YIN Yao-feng | Yongxing Sino-Platinum Metals Resources Co.Ltd., Chenzhou 423399, Hunan, China | | YUAN Yuan | Yongxing Sino-Platinum Metals Resources Co.Ltd., Chenzhou 423399, Hunan, China | |
|
Hits: 730 |
Download times: 451 |
中文摘要: |
采用水合肼还原重量法测定草酸银中银含量,平行测定5次,测定的相对标准偏差小于0.04%,加标回收率99.96%~100.02%,干扰试验显示:0.1 mg的Zn2+、Co2+、Ni2+、Cu2+、Cd2+不干扰银的测定。该法与其他方法相对比,样品取样量大,操作简单,可满足生产现场测定的要求。 |
英文摘要: |
The silver content in silver oxalate is determined by the hydrazine hydrate reduction gravimetric method, whose determination is performed 5 times in parallel. The relative standard deviation of the determination is less than 0.04%, and the recovery rate of standard addition is 99.96%~100.02%.The interference test showed that 0.1 mg of Zn2+, Co2+, Ni2+, Cu2+, Cd2+ did not interfere with the determination of silver. Compared with other methods, this method has a large sample size and simple operation, which can meet the requirements of production site measurement. |
View Full Text
View/Add Comment Download reader |
Close |
|
|
|