Abstract
内标控制-ICP-AES法测定镍铂合金中铂含量
Internal standard control-determination of platinum content in Ni-Pt alloy by ICP-AES
Received:July 24, 2023  
DOI:
中文关键词: 内标控制  电感耦合等离子体原子发射光谱法(ICP-AES)  镍铂合金  
英文关键词: internal standard control  inductively coupled plasma atomic emission spectroscopy (ICP-AES)  nickel-platinum alloy  platinum
基金项目:国家标准制定任务(20213153-T-610)
Author NameAffiliation
ZHAO Wanchun State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals,Sino-Platinum Metals Co. Ltd., Sino-Platinum Metals Testing Technology Yunnan Co. Ltd., Kunming 650106, China 
LI Qiuying State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals,Sino-Platinum Metals Co. Ltd., Sino-Platinum Metals Testing Technology Yunnan Co. Ltd., Kunming 650106, China 
SUN Qi State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals,Sino-Platinum Metals Co. Ltd., Sino-Platinum Metals Testing Technology Yunnan Co. Ltd., Kunming 650106, China 
ZHAO Wenhu State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals,Sino-Platinum Metals Co. Ltd., Sino-Platinum Metals Testing Technology Yunnan Co. Ltd., Kunming 650106, China 
YANG Hui State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals,Sino-Platinum Metals Co. Ltd., Sino-Platinum Metals Testing Technology Yunnan Co. Ltd., Kunming 650106, China 
Hits: 159
Download times: 86
中文摘要:
      镍铂合金中铂含量的准确测定是生产物料金属平衡考察和交易中的重要指标,以往常采用稀释后用ICP-AES进行测定,但是该法稀释过程易引入误差。采用钇内标测定控制,试样以盐酸-硝酸溶解后,在15%的盐酸介质中,用ICP-AES法测定镍铂合金中铂含量。对谱线选择,基体镍的影响,仪器最佳测定条件等进行实验,建立了一种ICP-AES法准确测定镍铂合金中铂含量的方法。方法的检出限(μg/mL)为0.029(Pt 204.937)、0.046(Pt 299.797)、0.035(Pt 265.945),测定范围为:1.0%~15.0%,加标回收率为:99.1%~101.6%,相对标准偏差(RSD)<1%。方法准确、快速、简便。结果与滴定法测定的结果吻合。
英文摘要:
      Accurate determination of platinum content in nickel-platinum alloy. It is an important index in material balance inspection and trade. In the past, diluted Inductively coupled plasma atomic emission spectroscopy were used, but the dilution process of this method is easy to introduce error. Yttrium internal standard measurement control. The sample was dissolved by hydrochloric acid and nitric acid, in 15% hydrochloric acid medium. The method of Accurate determination of platinum content in Ni-Pt alloy target by ICP-AES is established. the influencing factors, including the line selection, effect of matrix nickel, instrument determination conditions, were been experimented. The detection limits (μg/mL) of the method were 0.029 for (Pt 204.937), 0.046 for (Pt 299.797), 0.035 for (Pt 265.945). The determination levels of the platinum in the range from 1.00% to 15.00%. The standard recoveries are from 99.1% to 101.6%, RSD<1%. The method is accurate, fast and simple. The results were in good agreement with those obtained by Titrimetric determination.